Insert UGR Calculation Point and UGR Calculation Area

30 августа 2012 - Админ

    You can insert UGR calculation points and UGR calculation areas via Drag and Drop from the furniture tree into the CAD. NOTE: If you place these objects into the ground plan, they are inserted at a default height of 1.2 m. This is the standard value that is used for a sitting observer. If you place them into the 3D view, they are placed on the surface you “touch” with your mouse. For example if you place them into the 3D view of an empty room they are positioned on the floor at a height Z=0.

Insert UGR objects into a room
    Fig. 299 Insert UGR objects into a room

    A second way to insert these objects is to use the Property Page. You just enter the numerical values of the position, the size and the rotation and click on Insert. It is the same Property Page that you can use to modify an existing object.